Home / Blog / Pumps, filters, tubing and fittings around a UAT air trap

Pumps, filters, tubing and fittings around a UAT air trap

Published by UAT on 27 November 2026.

An air trap is one vessel in a chain

An air trap is one vessel in a fuel-system chain, not the complete system around it. The illustrative layout published by gquat is:

Main tank → optional header tank → UAT → pump → engine

That sequence helps explain the parts’ roles, but it is not a universal installation drawing. Airframes differ in tank arrangement, plumbing, pump position and control method, so the airframe and engine manuals must determine the final installation.

UAT tanks are fuel-system accessories, not engines. The sold capacities are 180CC/180 mL and 280CC/280 mL. gquat’s UAT tank pages do not sell the pump. This article instead examines the components that work around a trap: the pump, filters, tubing, fittings, valves and branch connections.

A header tank and an air trap can also perform different jobs in the same installation. A header tank is generally a reservoir arranged to help a pickup remain flooded during manoeuvres; an air trap is intended to give separated air a place to collect before fuel continues toward the pump. For a fuller comparison, see What is a UAT air trap tank, and how does it differ from a header tank?.

The pump and its two sides

In the published fuel path, the pump draws fuel from the air trap and delivers it toward the engine. In many model-turbine installations, pump operation is commanded by the engine’s electronic control unit, although the exact arrangement and control sequence depend on the engine and airframe.

The distinction between the suction side and pressure side is important when diagnosing an installation:

Public hobby notes associated with BVM commonly distinguish between leaks on these two sides, particularly when discussing Festo-style pressure-side connections and barbed suction-side connections. Those observations are general installation guidance, not UAT specifications.

Some Swiwin manuals describe brushless fuel pumps, illustrating one way an engine system may be built. That does not make a particular pump a UAT accessory, nor does it establish compatibility with any named engine. Pump voltage, flow, priming behaviour and control connections should be taken from the engine maker’s documentation rather than inferred from the air-trap tank.

A pump also does not make an inadequately arranged fuel system immune to air. It still needs a supply that remains suitably flooded and free of restrictions. The UAT’s specially designed internal structure is intended to help keep air out of the fuel feed toward the pump, but results still depend on the rest of the installation.

Filters: three different jobs

The word filter can describe several different components in a model-turbine fuel system. They should not be treated as interchangeable.

1. Filtering during filling

A filter used while filling a fuel can or the aircraft tank is intended to stop contaminants before they enter the main fuel supply. Its capacity, micron rating and maintenance procedure belong to the filter product and the fueling arrangement, not to the UAT by implication.

gquat also publishes a separate ground fueling station for field refueling and defueling of model-aircraft tanks. It can be paired with UAT tanks in an aircraft fuel system. The station’s separate component list does not define the specification of a UAT filter.

2. A felt pickup or felt assembly in a tank

A felt pickup or clunk sits inside a fuel tank and helps draw fuel from the lowest available part of that tank. It is part of the tank arrangement rather than a separate fine-filter housing.

UAT photographs and published material show a clear cylinder with a visible internal assembly. That observation should not be converted into a micron rating or an unsupported claim about how finely that assembly filters fuel.

3. A separate in-line filter

An in-line filter is a distinct component installed in a fuel line. Public BVM notes place some examples downstream of the pump and recommend a vertical installation, but that is not a universal arrangement for every airframe. Position, orientation, restriction and service access should follow the engine and airframe documentation.

For UAT configurations, the published filter options are 304 stainless steel mesh or filter cotton. gquat has not published a micron rating, foam specification or wash interval for those options. Configuration-specific questions should be sent to yxs@njgq.net.

Tubing: material, dimensions and routing

Fuel tubing must be compatible with the fuel used by the engine, including its lubricant. Tygon and Festo PU tubing are commonly discussed in public model-turbine fuel-system material, but neither is identified here as a UAT-supplied tube specification.

Nominal sizes of 4 mm and 6 mm, and sometimes larger sizes, also appear widely in forums and some manuals. Those figures are not published UAT specifications. A tube’s outside diameter, inside diameter, wall construction, material and fitting compatibility all matter, and a nominal diameter alone does not establish whether a line will perform correctly.

Good routing also protects the tube as well as the joint. Lines should be secured against vibration, abrasion and movement, and should not be bent into a tight radius or kinked. BVM’s public notes specifically advise cutting hose square and avoiding sharp bends close to push-in fittings. A square cut reduces the chance that the tube edge will sit unevenly or obstruct flow inside the connector.

Whenever tubing is replaced, inspect the entire route rather than only the new section. A new tube can be correct while the surrounding clips, bends, unions or tank penetrations remain the actual source of a leak. Follow the tubing and fitting makers’ instructions and the aircraft manufacturer’s fuel-system layout.

Fittings and the meaning of FESTO G1/8

UAT tanks are published as FESTO G1/8 compatible. FESTO G1/8 is described as a common quick-connect thread size, but it does not by itself tell the reader which tube outside diameter or inside diameter to use. The site does not publish the thread pitch, a hose-size assignment for each port, or a universal tubing chart for the tanks.

The tank’s end caps are marked Tank, Engine and Fill. Those labels describe the intended roles of the connections; they are not a substitute for the installation diagram supplied with an aircraft or engine system. A tank marked “Fill” should not automatically be treated as the fuel-filling point on every installation.

The UAT tank pages also do not list a fitting as a standalone SKU. Confirm the contents of the package and the requirements of the selected connector before ordering additional parts.

Public BVM notes often recommend Festo-style push-in fittings on the pressure side and barbed fittings on the suction side. They also discuss using safety wire on non-Festo barbed connections. These are attributed third-party recommendations, not UAT requirements. FESTO G1/8 compatibility alone does not determine whether a particular fitting style is suitable for every side of every installation.

BVM is cited here only as an independent source of public hobby-system guidance. UAT is not affiliated with BVM, and the recommendations should not be presented as a BVM compatibility statement or a UAT guarantee. Follow the airframe, engine and fitting documentation for the completed system.

Valves, tees and branch connections

A manual shutoff valve can provide a means of isolating part of a fuel system during filling, inspection or maintenance. Some start systems also use solenoid valves as part of their fuel-control arrangement. Their purpose and energized or de-energized state vary, so neither the presence nor the position of a valve should be assumed from a generic air-trap diagram.

T-pieces or similar branch fittings are used where a system must divide one fuel path into several connections. This matters in multi-tank layouts, where the piping arrangement can affect which tank empties first and whether a pickup remains covered. A tee is only a connection component; it does not establish a correct tank topology by itself.

The same distinction applies to headers and air traps. They can appear together, but one does not automatically replace the other. The existing article on header tanks and air traps explains those roles without treating the terms as unqualified synonyms.

Any valve, tee or branch arrangement should be based on the airframe and engine manuals. The labels on the UAT caps provide useful orientation, but they cannot determine the correct shutoff position or multi-tank plumbing.

What UAT publishes—and what it does not

TopicPublished UAT informationInformation that should not be inferred
Capacities180CC and 280CCA flow rating, flight-time rating or engine-size chart
MaterialPC + ABSWhich individual part uses which material
ConnectionFESTO G1/8 compatibleThread pitch, hose OD/ID or a port-to-hose-size chart
Filter options304 stainless steel mesh or filter cottonA micron rating, foam type or published wash interval
Cap labelsTank, Engine and FillA universal installation or plumbing order
Visible constructionClear cylinder with a visible internal assemblyA performance guarantee or specific filtration level
Illustrative pathMain tank → optional header tank → UAT → pump → engineA mandatory layout for every airframe
Engine compatibilityNo engine-brand compatibility list is publishedApproval for JetCat, Xicoy, Kingtech, Swiwin or another named maker

Limits of this component guide

This page is an educational component explainer, not an installation manual or a substitute for the manuals supplied with the aircraft, engine, pump, tubing or fittings.

The UAT is intended to help keep air out of the fuel feed toward the pump. It does not guarantee bubble-free fuel, zero air or prevention of flameouts. Residual air is possible, and the result depends on the rest of the fuel-system installation.

Likewise, third-party advice about filter position, fitting styles, tubing dimensions or pump types describes those manufacturers’ systems and general hobby practice. It does not turn any of those details into a UAT specification. The 180CC and 280CC planning guide provides the appropriate system-based approach to capacity selection without treating either tank as a guaranteed flight-time or engine-size match.

Frequently asked questions

Does the pump always come after the UAT?

The published illustrative path places the UAT before the pump, but it is not a universal installation rule. The pump and plumbing must be arranged according to the airframe and engine documentation.

Does gquat sell a pump or standalone fittings with the UAT?

The UAT tank pages do not list the pump as a product, and no standalone fitting SKU is shown on those pages. The separate ground fueling station has a published field fill-and-defuel role. Check the current package contents and contact gquat if the supplied arrangement is unclear.

What size tubing should be connected to a UAT?

gquat has not published a UAT hose OD or ID. The 4 mm and 6 mm sizes found in hobby discussions are not UAT specifications. Match the tube to the selected connector and follow the engine and airframe manuals.

Does FESTO G1/8 tell me which tube to use?

No. It identifies the published quick-connect thread compatibility. It does not provide the tube outside diameter, inside diameter, thread pitch or a complete port-by-port tubing chart.

Does the UAT filter have a micron rating?

No micron rating is published for the UAT’s 304 stainless steel mesh or filter cotton options. Ask gquat for configuration-specific specifications rather than applying a rating published for another product.

Must an in-line filter be installed after the pump and vertically?

Some BVM notes describe that arrangement, but it is not a universal requirement. Filter placement and orientation should follow the airframe and engine documentation.

Should every connection use Festo-style push-in fittings?

No universal rule can be drawn from UAT G1/8 compatibility. Public notes associated with BVM discuss different fitting approaches for suction and pressure sides. Select and install fittings according to the completed system rather than treating that advice as a UAT requirement.

Does the UAT guarantee bubble-free fuel or prevent flameouts?

No. It is intended to help keep air out of the fuel feed toward the pump, but residual air remains possible. Fuel delivery also depends on the pump, tubing, fittings, tank arrangement, vents and the rest of the installation.

Sources

gquat.com pages

Other parties’ public documentation

No engines or UAT units were tested for this article.